Please use this identifier to cite or link to this item: https://dspace.univ-adrar.edu.dz/jspui/handle/123456789/5743
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAdel, warda
dc.contributor.authorBouregbaoui, wahiba
dc.contributor.authorArbaoui, Iliace / promoteur
dc.date.accessioned2021-11-28T13:20:26Z
dc.date.available2021-11-28T13:20:26Z
dc.date.issued2021
dc.identifier.urihttps://dspace.univ-adrar.edu.dz/jspui/handle/123456789/5743
dc.descriptionPhysique Énergétiqueen_US
dc.description.abstractLa modélisation erronée des puissances de distribution sur l'ensemble du réseau électrique peut conduire vers l'instabilité partielle ou globale, ce qui provoque des pertes d'énergie plus élevées et une mauvaise régulation de tension et de fréquence. Dans ce travail, nous avons analysé, modélisé et étudié le réseau IEEE de distribution électrique à 30 bus connectés en 6 générateurs dont deux présente un système de production photovoltaïque et l’autre une éolienne. On a s’intéressé au régime permanent pour l’ensemble du système électrique. Les résultats obtenus montrent que le contrôle des tensions (AVR) et des puissances réactives de chaque nœud garde le système dans les intervalles de fonctionnement admissible, à travers le contrôle initial des prises des autotransformateurs (LTC), et la compensation de réactive partielle et globale pour les nœuds qui ont des violations de tension critique au niveau des sous-postes de distribution. Les solutions proposées réduiront les pertes actives totales du réseau à 39%. L'étude et la modélisation du réseau ont été effectuées en utilisant un programme d'algorithmes développé visant à simuler les réseaux électriques.en_US
dc.description.abstractWrong modeling of distribution powers over the entire electrical network can lead to partial or global instability, which causes higher energy losses and poor voltage and frequency regulation. In this work, we have analyzed, modeled and studied the IEEE electrical distribution network with 30 buses connected in 6 generators, two of which have a photovoltaic production system and the other a wind turbine. We looked at the steady state for the entire electrical system. The results obtained show that the control of the voltages (AVR) and the reactive powers of each node keeps the system within the permissible operating intervals, through the initial control of the taps of the autotransformers (LTC), and the partial and global reactive compensation. for nodes that have critical voltage violations at distribution substations. The proposed solutions will reduce the total active losses of the network to 39%. The study and the modeling of the network were carried out using a program of algorithms developed to simulate the electrical networks.
dc.language.isofren_US
dc.publisherUNIVERSITE AHMED DRAIA- ADRARen_US
dc.subjectl'énergieen_US
dc.subjectles énergie renouvelableen_US
dc.subjectle soleilen_US
dc.subjectun éolienneen_US
dc.subjectun réseau électriqueen_US
dc.subjectle systemen_US
dc.titleL'impact de la productivité d' énergie renouvelable sur les charges électriquesen_US
dc.typeThesisen_US
Appears in Collections:Mémoires de Master

Files in This Item:
File Description SizeFormat 
L'impact de la productivité d' énergie renouvelable sur les charges électriques.pdf7.84 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.